FEM ConstraintHeatflux: Difference between revisions

From FreeCAD Documentation
(button name update)
(added dflux mode)
Line 23: Line 23:


<!--T:6-->
<!--T:6-->
Defines a convective heat flux load on a surface at a temperature ''T'' with a film coefficient ''h'' and with the environment (sink) temperature ''T<sub>0</sub>''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)'''''
Defines a convective heat flux load on a surface at a temperature ''T'' with a film coefficient ''h'' and with the environment (sink) temperature ''T<sub>0</sub>''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)'''''. Optionally, can also define a regular surface heat flux.


==Usage== <!--T:3-->
==Usage== <!--T:3-->

Revision as of 17:40, 12 November 2023

FEM ConstraintHeatflux

Menu location
Model → Thermal boundary conditions and loads → Heat flux load
Workbenches
FEM
Default shortcut
None
Introduced in version
-
See also
FEM tutorial

Description

Defines a convective heat flux load on a surface at a temperature T with a film coefficient h and with the environment (sink) temperature T0. The convective heat flux q will satisfy: q = h(T -T0). Optionally, can also define a regular surface heat flux.

Usage

  1. There are several ways to invoke the command:
    • Press the Heat flux load button.
    • Select the Model → Thermal boundary conditions and loads → Heat flux load option from the menu.
  2. In the 3D view select the face(s) the constraint should be applied to.
  3. Enter the desired surface temperature, heat transfer coefficient and environment temperature.

Notes