FEM ConstraintHeatflux/ru: Difference between revisions

From FreeCAD Documentation
(Updating to match new version of source page)
(Updating to match new version of source page)
(3 intermediate revisions by the same user not shown)
Line 23: Line 23:
==Description==
==Description==


Defines a convective heat flux load on a surface at a temperature ''T'' with a film coefficient ''h'' and with the environment (sink) temperature ''T<sub>0</sub>''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)'''''
Defines a convective heat flux load on a surface at a temperature ''T'' with a film coefficient ''h'' and with the environment (sink) temperature ''T<sub>0</sub>''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)'''''. Optionally, can also define a regular surface heat flux load.


==Usage==
==Usage==


# There are several ways to invoke the command:
# There are several ways to invoke the command:
#* Press the {{Button|[[Image:FEM_ConstraintHeatflux.svg|16px]] [[FEM_ConstraintHeatflux|FEM ConstraintHeatflux]]}} button.
#* Press the {{Button|[[Image:FEM_ConstraintHeatflux.svg|16px]] [[FEM_ConstraintHeatflux|Heat flux load]]}} button.
#* Select the {{MenuCommand|Model → Thermal Constraints → [[Image:FEM_ConstraintHeatflux.svg|16px]] Constraint heatflux}} option from the menu.
#* Select the {{MenuCommand|Model → Thermal boundary conditions and loads → [[Image:FEM_ConstraintHeatflux.svg|16px]] Heat flux load}} option from the menu.
# In the [[3D_view|3D view]] select the face(s) the constraint should be applied to.
# In the [[3D_view|3D view]] select the face(s) the heat flux load should be applied to.
# Enter the desired surface temperature, heat transfer coefficient and environment temperature.
# Enter the desired heat transfer coefficient and environment temperature.


==Notes==
===Option===


By default, this feature defines a convective heat flux. By using the option '''Surface heat flux''', one can specify a heat flux value in Watts per surface area (W/m^2).
* The constraint uses the *FILM card in CalculiX. The heatflux constraint is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html

==Notes==


* The heat flux load uses the *FILM card in CalculiX. It is explained at http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html
* The '''Surface heat flux''' option uses the *DFLUX card in CalculiX: http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node188.html


{{Docnav/ru
{{Docnav/ru
Line 49: Line 53:
{{FEM Tools navi{{#translation:}}}}
{{FEM Tools navi{{#translation:}}}}
{{Userdocnavi{{#translation:}}}}
{{Userdocnavi{{#translation:}}}}
{{clear}}

Revision as of 13:27, 24 November 2023

Other languages:

FEM ConstraintHeatflux

Системное название
FEM ConstraintHeatflux
Расположение в меню
Model → Thermal Constraints → Constraint heatflux
Верстаки
FEM
Быстрые клавиши
Нет
Представлено в версии
-
См. также
FEM tutorial

Description

Defines a convective heat flux load on a surface at a temperature T with a film coefficient h and with the environment (sink) temperature T0. The convective heat flux q will satisfy: q = h(T -T0). Optionally, can also define a regular surface heat flux load.

Usage

  1. There are several ways to invoke the command:
    • Press the Heat flux load button.
    • Select the Model → Thermal boundary conditions and loads → Heat flux load option from the menu.
  2. In the 3D view select the face(s) the heat flux load should be applied to.
  3. Enter the desired heat transfer coefficient and environment temperature.

Option

By default, this feature defines a convective heat flux. By using the option Surface heat flux, one can specify a heat flux value in Watts per surface area (W/m^2).

Notes