==Beschreibung==
==Beschreibung==


Defines a convective heat flux load on a surface at a temperature ''T'' with a film coefficient ''h'' and with the environment (sink) temperature ''T<sub>0</sub>''. The convective heat flux ''q'' will satisfy: '''''q = h(T -T<sub>0</sub>)'''''. Optionally, can also define a regular surface heat flux load.
By default, defines a convective heat flux load on a surface at a temperature <math>T</math> with a film coefficient <math>h</math> and with the environment (sink/ambient) temperature <math>T_{0}</math>. The convective heat flux <math>q</math> will satisfy: <math>q=h(T-T_{0})</math>. Optionally, can also define a regular surface heat flux load.


{{Version|1.0}}: Can be also used to define a radiation heat flux on a surface.
{{Version|1.0}}: Can be also used to define a radiation heat flux on a surface. It satisfies: <math>q=\epsilon \sigma(T^{4}-T_{0}^{4})</math> where <math>\epsilon</math> is the surface emissivity and <math>\sigma</math> is the Stefan-Boltzmann constant.


<span id="Usage"></span>
<span id="Usage"></span>
==Anwendung==
==Anwendung==


<div class="mw-translate-fuzzy">
# Es gibt mehrere Möglichkeiten, den Befehl aufzurufen:
# Es gibt mehrere Möglichkeiten, den Befehl aufzurufen:
#* Die Schaltfläche {{Button|[[Image:FEM_ConstraintHeatflux.svg|16px]] [[FEM_ConstraintHeatflux/de|Wärmestrombelastung]]}} drücken.
#* Die Schaltfläche {{Button|[[Image:FEM_ConstraintHeatflux.svg|16px]] [[FEM_ConstraintHeatflux/de|Wärmestrombelastung]]}} drücken.
Line 33: Line 34:
# In der [[3D_view/de|3D-Ansicht]] die Fläche(n) auswählen, auf die die Wärmestrombelastung angewendet werden soll.
# In der [[3D_view/de|3D-Ansicht]] die Fläche(n) auswählen, auf die die Wärmestrombelastung angewendet werden soll.
# Die gewünschten Werte für Wärmeübergangskoeffizient und Umgebungstemperatur eingeben.
# Die gewünschten Werte für Wärmeübergangskoeffizient und Umgebungstemperatur eingeben.
</div>

<span id="Options"></span>
===Optionen===

Standardmäßig legt dieses Werkzeug einen Konvektionswärmefluss fest. Durch aktivieren der Option '''Oberflächenwärmefluss''' (?) (Surface heat flux) kann ein Wärmeflusswert in Watt pro Quadratmeter Oberfläche (W/m^2).

{{Version/de|1.0}}: Durch Aktivieren der Option '''Oberflächenstrahlung''' kann ein Strahlungswärmefluss festgelegt werden, indem eine geeigneter Oberflächenstrahlungssbeiwert (?) (surface emissivity) und eine Umgebungtemperatur festgelegt werden.


<span id="Notes"></span>
<span id="Notes"></span>
==Hinweise==
==Hinweise==


* The heat flux load uses the [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html *FILM card in CalculiX].
* The heat flux load uses the following CalculiX cards depending on the selected mode:
* The '''Surface heat flux''' option uses the [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node188.html *DFLUX card in CalculiX].
** [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node203.html *FILM] for ''Surface Convection''
* {{Version|1.0}}: The '''Surface Radiation''' option uses the [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node234.html *RADIATE card in CalculiX].
** {{Version|1.0}}: [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node234.html *RADIATE] for ''Surface Radiation''
** [http://web.mit.edu/calculix_v2.7/CalculiX/ccx_2.7/doc/ccx/node188.html *DFLUX] for ''Surface heat flux''





Latest revision as of 12:14, 22 May 2024

FEM RandbedingungWärmestrom

Menüeintrag
Modell → Thermische Randbedingungen und Belastungen → Wärmestrombelastung
Arbeitsbereich
FEM
Standardtastenkürzel
Keiner
Eingeführt in Version
-
Siehe auch
FEM-Anleitung

Beschreibung

By default, defines a convective heat flux load on a surface at a temperature with a film coefficient and with the environment (sink/ambient) temperature . The convective heat flux will satisfy: . Optionally, can also define a regular surface heat flux load.

introduced in version 1.0: Can be also used to define a radiation heat flux on a surface. It satisfies: where is the surface emissivity and is the Stefan-Boltzmann constant.

Anwendung

  1. Es gibt mehrere Möglichkeiten, den Befehl aufzurufen:
    • Die Schaltfläche Wärmestrombelastung drücken.
    • Den Menüeintrag Modell → Thermische Randbedingungen und Belastungen → Wärmestrombelastung auswählen.
  2. In der 3D-Ansicht die Fläche(n) auswählen, auf die die Wärmestrombelastung angewendet werden soll.
  3. Die gewünschten Werte für Wärmeübergangskoeffizient und Umgebungstemperatur eingeben.

Hinweise