FEM EquationFlux/de: Difference between revisions
No edit summary |
(Updating to match new version of source page) |
||
(One intermediate revision by the same user not shown) | |||
Line 28: | Line 28: | ||
# After adding an Elmer solver as described [[FEM_SolverElmer#Equations|here]], select it in the [[Tree_view|tree view]]. |
# After adding an Elmer solver as described [[FEM_SolverElmer#Equations|here]], select it in the [[Tree_view|tree view]]. |
||
# Either use the toolbar button [[Image:FEM_EquationFlux.svg|24px]] or the menu {{MenuCommand|Solve → Flux equation}}. |
# Either use the toolbar button [[Image:FEM_EquationFlux.svg|24px]] or the menu {{MenuCommand|Solve → Flux equation}}. |
||
# Now either add a heat equation (toolbar button [[Image:FEM_EquationHeat.svg|24px]] or menu {{MenuCommand|Solve → [[FEM_EquationHeat|Heat equation]]}}) or an electrostatic equation (toolbar button [[Image:FEM_EquationElectrostatic.svg|24px]] or menu {{MenuCommand|Solve → [[FEM_EquationElectrostatic|Electrostatic equation]]}}). This is important because the flux equation needs the |
# Now either add a heat equation (toolbar button [[Image:FEM_EquationHeat.svg|24px]] or menu {{MenuCommand|Solve → [[FEM_EquationHeat|Heat equation]]}}) or an electrostatic equation (toolbar button [[Image:FEM_EquationElectrostatic.svg|24px]] or menu {{MenuCommand|Solve → [[FEM_EquationElectrostatic|Electrostatic equation]]}}). This is important because the flux equation needs the boundary conditions set for these equations. |
||
# When using the electrostatic equation, change the property {{PropertyData|Flux Coefficient}} to ''None''. and the property {{PropertyData|Flux Variable}} to ''Potential''. |
# When using the electrostatic equation, change the property {{PropertyData|Flux Coefficient}} to ''None''. and the property {{PropertyData|Flux Variable}} to ''Potential''. |
||
# Change the [[#Solver_Settings|equation's solver settings]] or the [[FEM_SolverElmer_SolverSettings|general solver settings]] if necessary. |
# Change the [[#Solver_Settings|equation's solver settings]] or the [[FEM_SolverElmer_SolverSettings|general solver settings]] if necessary. |
||
Line 37: | Line 37: | ||
The flux equation provides these special settings: |
The flux equation provides these special settings: |
||
* {{PropertyData|Average Within Materials}}: If |
* {{PropertyData|Average Within Materials}}: If {{TRUE}}, continuity is enforced within the same material in the discontinuous Galerkin discretization using the penalty terms of the discontinuous Galerkin formulation. |
||
* {{PropertyData|Calculate Flux}}: Calculates the flux vector. |
* {{PropertyData|Calculate Flux}}: Calculates the flux vector. |
||
* {{PropertyData|Calculate Flux Abs}}: Calculates the absolute of the flux vector. Requires that {{PropertyData|Calculate Flux}} is |
* {{PropertyData|Calculate Flux Abs}}: Calculates the absolute of the flux vector. Requires that {{PropertyData|Calculate Flux}} is {{TRUE}}. |
||
* {{PropertyData|Calculate Flux Magnitude}}: Computes the magnitude of the vector field. Requires that {{PropertyData|Calculate Flux}} is |
* {{PropertyData|Calculate Flux Magnitude}}: Computes the magnitude of the vector field. Requires that {{PropertyData|Calculate Flux}} is {{TRUE}}.</br>Basically it is the same as {{PropertyData|Calculate Flux Abs}} but this requires less memory because it solves the matrix equation only once. The downside is that negative values may be introduced. |
||
* {{PropertyData|Calculate Grad}}: Calculates the gradient of the flux. |
* {{PropertyData|Calculate Grad}}: Calculates the gradient of the flux. |
||
* {{PropertyData|Calculate Grad Abs}}: Calculates the absolute flux gradient. Requires that {{PropertyData|Calculate Grad}} is |
* {{PropertyData|Calculate Grad Abs}}: Calculates the absolute flux gradient. Requires that {{PropertyData|Calculate Grad}} is {{TRUE}}. |
||
* {{PropertyData|Calculate Grad Magnitude}}: Computes the magnitude of the vector field. Requires that {{PropertyData|Calculate Grad}} is |
* {{PropertyData|Calculate Grad Magnitude}}: Computes the magnitude of the vector field. Requires that {{PropertyData|Calculate Grad}} is {{TRUE}}.</br>Basically it is the same as {{PropertyData|Calculate Grad Abs}} but this requires less memory because it solves the matrix equation only once. The downside is that negative values may be introduced. |
||
* {{PropertyData|Discontinuous Galerkin}}: For discontinuous fields the standard Galerkin approximation enforces continuity which may be unphysical. As a remedy for this, set this property to |
* {{PropertyData|Discontinuous Galerkin}}: For discontinuous fields the standard Galerkin approximation enforces continuity which may be unphysical. As a remedy for this, set this property to {{TRUE}}. Then the result may be discontinuous and may even be visualized as such. |
||
* {{PropertyData|Enforce Positive Magnitude}}: If |
* {{PropertyData|Enforce Positive Magnitude}}: If {{TRUE}}, the negative values of the computed magnitude fields are set to zero. |
||
* {{PropertyData|Flux Coefficient}}: Name of the proportionality coefficient to compute the flux. |
* {{PropertyData|Flux Coefficient}}: Name of the proportionality coefficient to compute the flux. |
||
* {{PropertyData|Flux Variable}}: Name of the potential variable used to compute the gradient. |
* {{PropertyData|Flux Variable}}: Name of the potential variable used to compute the gradient. |
||
== |
==Analysis Feature Information== |
||
The flux equation does not have own |
The flux equation does not have its own boundary conditions. It takes the boundary conditions from the [[Image:FEM_EquationHeat.svg|24px]] [[FEM_EquationHeat|Heat equation]] or the [[Image:FEM_EquationElectrostatic.svg|24px]] [[FEM_EquationElectrostatic|Electrostatic equation]]. |
||
<span id="Results"></span> |
<span id="Results"></span> |
||
==Ergebnisse== |
==Ergebnisse== |
||
The available results depend on the [[#Solver_Settings|solver settings]]. If none of the {{PropertyData|Calculate *}} settings was set to |
The available results depend on the [[#Solver_Settings|solver settings]]. If none of the {{PropertyData|Calculate *}} settings was set to {{TRUE}}, nothing is calculated. Otherwise the corresponding results will also be available. |
||
Die resultierende Flussgröße ist entweder der Wärmefluss <math>\rm W/m^2</math> (fälschlicher Weise auch "Temperaturfluss" genannt) oder der Potentialfluss (<-?) in <math>\rm W/m^2</math> (<math>\rm A\cdot V/m^2</math>). |
Die resultierende Flussgröße ist entweder der Wärmefluss <math>\rm W/m^2</math> (fälschlicher Weise auch "Temperaturfluss" genannt) oder der Potentialfluss (<-?) in <math>\rm W/m^2</math> (<math>\rm A\cdot V/m^2</math>). |
||
Line 72: | Line 72: | ||
{{FEM Tools navi{{#translation:}}}} |
{{FEM Tools navi{{#translation:}}}} |
||
{{Userdocnavi{{#translation:}}}} |
{{Userdocnavi{{#translation:}}}} |
||
{{clear}} |
Latest revision as of 13:22, 24 November 2023
FEM GleichungFluss |
Menüeintrag |
---|
Lösen → Flux equation |
Arbeitsbereich |
FEM |
Standardtastenkürzel |
Keiner |
Eingeführt in Version |
0.17 |
Siehe auch |
Keiner |
Diese Gleichung wird für die Berechnung der Flussgrößen verwendet, die normalerweise aus poisson-artigen Gleichungen resultieren. Diese enthalten die FEM GleichungWärme und die FEM GleichungElektrostatik.
For info about the math of the equation, see the Elmer models manual, section Flux Computation.
Anwendung
- After adding an Elmer solver as described here, select it in the tree view.
- Either use the toolbar button or the menu Solve → Flux equation.
- Now either add a heat equation (toolbar button or menu Solve → Heat equation) or an electrostatic equation (toolbar button or menu Solve → Electrostatic equation). This is important because the flux equation needs the boundary conditions set for these equations.
- When using the electrostatic equation, change the property DatenFlux Coefficient to None. and the property DatenFlux Variable to Potential.
- Change the equation's solver settings or the general solver settings if necessary.
Solver Settings
For the general solver settings, see the Elmer solver settings.
The flux equation provides these special settings:
- DatenAverage Within Materials: If
true
, continuity is enforced within the same material in the discontinuous Galerkin discretization using the penalty terms of the discontinuous Galerkin formulation. - DatenCalculate Flux: Calculates the flux vector.
- DatenCalculate Flux Abs: Calculates the absolute of the flux vector. Requires that DatenCalculate Flux is
true
. - DatenCalculate Flux Magnitude: Computes the magnitude of the vector field. Requires that DatenCalculate Flux is
true
.
Basically it is the same as DatenCalculate Flux Abs but this requires less memory because it solves the matrix equation only once. The downside is that negative values may be introduced. - DatenCalculate Grad: Calculates the gradient of the flux.
- DatenCalculate Grad Abs: Calculates the absolute flux gradient. Requires that DatenCalculate Grad is
true
. - DatenCalculate Grad Magnitude: Computes the magnitude of the vector field. Requires that DatenCalculate Grad is
true
.
Basically it is the same as DatenCalculate Grad Abs but this requires less memory because it solves the matrix equation only once. The downside is that negative values may be introduced. - DatenDiscontinuous Galerkin: For discontinuous fields the standard Galerkin approximation enforces continuity which may be unphysical. As a remedy for this, set this property to
true
. Then the result may be discontinuous and may even be visualized as such. - DatenEnforce Positive Magnitude: If
true
, the negative values of the computed magnitude fields are set to zero. - DatenFlux Coefficient: Name of the proportionality coefficient to compute the flux.
- DatenFlux Variable: Name of the potential variable used to compute the gradient.
Analysis Feature Information
The flux equation does not have its own boundary conditions. It takes the boundary conditions from the Heat equation or the Electrostatic equation.
Ergebnisse
The available results depend on the solver settings. If none of the DatenCalculate * settings was set to true
, nothing is calculated. Otherwise the corresponding results will also be available.
Die resultierende Flussgröße ist entweder der Wärmefluss (fälschlicher Weise auch "Temperaturfluss" genannt) oder der Potentialfluss (<-?) in ().
- Materials: Solid, Fluid, Nonlinear mechanical, Reinforced (concrete); Material editor
- Element geometry: Beam (1D), Beam rotation (1D), Shell (2D), Fluid flow (1D)
Constraints
- Electromagnetic: Electrostatic potential, Current density, Magnetization
- Geometrical: Plane rotation, Section print, Transform
- Mechanical: Fixed, Displacement, Contact, Tie, Spring, Force, Pressure, Centrif, Self weight
- Thermal: Initial temperature, Heat flux, Temperature, Body heat source
- Overwrite Constants: Constant vacuum permittivity
- Solve: CalculiX Standard, Elmer, Mystran, Z88; Equations: Deformation, Elasticity, Electrostatic, Electricforce, Magnetodynamic, Magnetodynamic 2D, Flow, Flux, Heat; Solver: Solver control, Solver run
- Results: Purge, Show; Postprocessing: Apply changes, Pipeline from result, Warp filter, Scalar clip filter, Function cut filter, Region clip filter, Contours filter, Line clip filter, Stress linearization plot, Data at point clip filter, Filter function plane, Filter function sphere, Filter function cylinder, Filter function box
- Additional: Preferences; FEM Install, FEM Mesh, FEM Solver, FEM CalculiX, FEM Concrete; FEM Element Types
- Erste Schritte
- Installation: Herunterladen, Windows, Linux, Mac, Zusätzlicher Komponenten, Docker, AppImage, Ubuntu Snap
- Grundlagen: Über FreeCAD, Graphische Oberfläche, Mausbedienung, Auswahlmethoden, Objektname, Programmeinstellungen, Arbeitsbereiche, Dokumentstruktur, Objekteigenschaften, Hilf FreeCAD, Spende
- Hilfe: Tutorien, Video Tutorien
- Arbeitsbereiche: Std Base, Arch, Assembly, CAM, Draft, FEM, Inspection, Mesh, OpenSCAD, Part, PartDesign, Points, Reverse Engineering, Robot, Sketcher, Spreadsheet, Surface, TechDraw, Test Framework