FEM ConstraintCurrentDensity/de: Difference between revisions

From FreeCAD Documentation
(Created page with "{{Docnav/de |RandbedingungElectrostatischesPotential |RandbedingungMagnetisierung |FEM |IconL=FEM_ConstraintElectrostaticPotential.svg |IconR=FEM_ConstraintMagnetization.svg |IconC=Workbench_FEM.svg }}")
No edit summary
 
(16 intermediate revisions by 2 users not shown)
Line 13: Line 13:
|Name=FEM ConstraintCurrentDensity
|Name=FEM ConstraintCurrentDensity
|Name/de=FEM RandbedingungStromdichte
|Name/de=FEM RandbedingungStromdichte
|MenuLocation= ModelElectromagnetic ConstraintsConstraint current density
|MenuLocation= ModellElektromagnetische RandbedingungenRandbedingungStromdichte
|Workbenches=[[FEM_Workbench/de|FEM]]
|Workbenches=[[FEM_Workbench/de|FEM]]
|Version=1.0
|Version=0.21
|SeeAlso=[[FEM_EquationMagnetodynamic/de|MagnetodynamischeGleichung]], [[FEM_EquationMagnetodynamic2D/de|Magnetodynamische2DGleichung]]
|SeeAlso=[[FEM_EquationMagnetodynamic/de|GleichungElektrodynamik]], [[FEM_EquationMagnetodynamic2D/de|GleichungElektrodynamik2D]]
}}
}}


<span id="Description"></span>
<div lang="en" dir="ltr" class="mw-content-ltr">
==Description==
==Beschreibung==
</div>


Erstellt eine FEM-Randbedingung für die Stromdichte, zur Verwendung mit der [[FEM_EquationMagnetodynamic/de|magnetodynamischen Gleichung]] und der [[FEM_EquationMagnetodynamic2D/de|magnetodynamischen 2D-Gleichung]].
<div lang="en" dir="ltr" class="mw-content-ltr">
Creates a FEM constraint for the current density. To be used together with the [[FEM_EquationMagnetodynamic|Magnetodynamic]] and [[FEM_EquationMagnetodynamic2D|Magnetodynamic 2D]] equations.
</div>


<span id="Usage"></span>
<div lang="en" dir="ltr" class="mw-content-ltr">
==Usage==
==Anwendung==
</div>


# Die Schaltfläche {{Button|[[Image:FEM_ConstraintCurrentDensity.svg|16px]] [[FEM_ConstraintCurrentDensity/de|Randbedingung Stromdichte]]}} drücken oder den Menüeintrag {{MenuCommand|ModellElektromagnetische Randbedingungen → [[Image:FEM_ConstraintCurrentDensity.svg|16px]] Randbedingung Stromdichte}} auswählen.
<div lang="en" dir="ltr" class="mw-content-ltr">
# In der [[3D_view/de|3D-Ansicht]] das Objekt auswählen, dem die Randbedingung zugeordnet werden soll.
# Press the {{Button|[[Image:FEM_ConstraintCurrentDensity.svg|16px]] [[FEM_ConstraintCurrentDensity|FEM ConstraintCurrentDensity]]}} button or use the menu {{MenuCommand|ModelElectromagnetic Constraints → [[Image:FEM_ConstraintCurrentDensity.svg|16px]] Constraint current density}}.
# Die Schaltfläche {{Button|Hinzufügen}} Drücken.
# In the [[3D_view|3D view]] select the object the constraint should be applied to.
# Press the {{Button|Add}} button.
</div>


<span id="Options"></span>
<div lang="en" dir="ltr" class="mw-content-ltr">
==Options==
==Optionen==
</div>


<div lang="en" dir="ltr" class="mw-content-ltr">
<div lang="en" dir="ltr" class="mw-content-ltr">

Latest revision as of 15:40, 16 December 2023

Other languages:

FEM RandbedingungStromdichte

Menüeintrag
Modell → Elektromagnetische Randbedingungen → RandbedingungStromdichte
Arbeitsbereich
FEM
Standardtastenkürzel
Keiner
Eingeführt in Version
0.21
Siehe auch
GleichungElektrodynamik, GleichungElektrodynamik2D

Beschreibung

Erstellt eine FEM-Randbedingung für die Stromdichte, zur Verwendung mit der magnetodynamischen Gleichung und der magnetodynamischen 2D-Gleichung.

Anwendung

  1. Die Schaltfläche Randbedingung Stromdichte drücken oder den Menüeintrag Modell → Elektromagnetische Randbedingungen → Randbedingung Stromdichte auswählen.
  2. In der 3D-Ansicht das Objekt auswählen, dem die Randbedingung zugeordnet werden soll.
  3. Die Schaltfläche Hinzufügen Drücken.

Optionen

  • Current density_*_1: The real/imaginary part of the current density in x-direction in A/m².
    For other coordinate systems than Cartesian 3D, this will be the first coordinate of the system instead of x.
  • Current density_*_2: The real/imaginary part of the current density in y-direction in A/m².
    For other coordinate systems than Cartesian 3D, this will be the second coordinate of the system instead of y.
  • Current density_*_3: The real/imaginary part of the current density in z-direction in A/m².
    For other coordinate systems than Cartesian 3D, this will be the third coordinate of the system instead of z. If the coordinate system has no third coordinate, this setting will be ignored.
  • Current density_*_*_Disabled: Whether the corresponding parameter is disabled (assumed as unknown by the solver).