Start up and Configuration
This page shows the different ways to start FreeCAD and the most important configuration features.
Starting FreeCAD from the Command line
FreeCAD can be started normally, by double-clicking on its desktop icon or selecting it from the start menu, but it can also be started directly from the command line. This allows you to change soem of the default startup options.
Command line options
The command line options are subject of frequent changes, therefore it is a good idea to check the current options by typing:
FreeCAD --help
From the response you can read the possible parameters:
Usage: FreeCAD [options] File1 File2 ..... Allowed options: Generic options: -v [ --version ] print version string -h [ --help ] print help message -c [ --console ] start in console mode --response-file arg can be specified with '@name', too
Configuration: -l [ --write-log ] arg write a log file to default location(Run FreeCAD --h to see default location) --log-file arg Unlike to --write-log this allows to log to an arbitrary file -u [ --user-cfg] arg User config file to load/save user settings -s [ --system-cfg] arg System config file to load/save system settings -t [ --run-test ] arg test level -M [ --module-path ] arg additional module paths -P [ --python-path ] arg additional python paths
EX: (Windows)
"C:\Program Files\FreeCAD 0.14\bin\FreeCAD.exe" -M "N:\FreeCAD\Mod\Draft" -M "N:\FreeCAD\Mod\Part" -M "N:\FreeCAD\Mod\Drawing" -u "N:\FreeCAD\Config\user.cfg" -s "N:\FreeCAD\Config\system.cfg"
Response and config files
FreeCAD can read some of these options from a config file. This file must be in the bin path and must be named FreeCAD.cfg. Be aware that options specified in the command line override the config file!
Some operating system have very low limit of the command line length. The common way to work around those limitations is using response files. A response file is just a configuration file which uses the same syntax as the command line. If the command line specifies a name of response file to use, it's loaded and parsed in addition to the command line:
FreeCAD @ResponseFile.txt
or:
FreeCAD --response-file=ResponseFile.txt
Hidden options
There are a couple of options not visible to the user. These options are e.g. the X-Window parameters parsed by the Windows system:
- -display display, sets the X display (default is $DISPLAY).
- -geometry geometry, sets the client geometry of the first window that is shown.
- -fn or -font font, defines the application font. The font should be specified using an X logical font description.
- -bg or -background color, sets the default background color and an application palette (light and dark shades are calculated).
- -fg or -foreground color, sets the default foreground color.
- -btn or -button color, sets the default button color.
- -name name, sets the application name.
- -title title, sets the application title.
- -visual TrueColor, forces the application to use a TrueColor visual on an 8-bit display.
- -ncols count, limits the number of colors allocated in the color cube on an 8-bit display, if the application is using the QApplication::ManyColor color specification. If count is 216 then a 6x6x6 color cube is used (i.e. 6 levels of red, 6 of green, and 6 of blue); for other values, a cube approximately proportional to a 2x3x1 cube is used.
- -cmap, causes the application to install a private color map on an 8-bit display.
Running FreeCAD without User Interface
FreeCAD normally starts in GUI mode, but you can also force it to start in console mode by typing:
FreeCAD -c
from the command line. In console mode, no user interface will be displayed, and you will be presented with a python interpreter prompt. From that python prompt, you have the same functionality as the python interpreter that runs inside the FreeCAD GUI, and normal access to all modules and plugins of FreeCAD, excepted the FreeCADGui module. Be aware that modules that depend on FreeCADGui might also be unavailable.
Running FreeCAD as a python module
FreeCAD can also be used to run as a python module inside other applications that use python or from an external python shell. For that, the host python application must know where your FreeCAD libs reside. The best way to obtain that is to temporarily append FreeCAD's lib path to the sys.path variable. The following code typed from any python shell will import FreeCAD and let you run it the same way as in console mode:
import sys
sys.path.append("path/to/FreeCAD/lib") # change this by your own FreeCAD lib path
import FreeCAD
Once FreeCAD is loaded, it is up to you to make it interact with your host application in any way you can imagine!
The Config set
On every Startup FreeCAD examines its surrounding and the command line parameters. It builds up a configuration set which holds the essence of the runtime information. This information is later used to determine the place where to save user data or log files. It is also very important for post postmortem analyzes. Therefore it is saved in the log file.
Config var name | Synopsis | Example M$ | Example Posix (Linux) |
---|---|---|---|
UserAppData | Path where FreeCAD stores User Related application data. | C:\Documents and Settings\username\Application Data\FreeCAD | /home/username/.FreeCAD |
UserParameter | File where FreeCAD stores User Related application data. | C:\Documents and Settings\username\Application Data\FreeCAD\user.cfg | /home/username/.FreeCAD/user.cfg |
SystemParameter | File where FreeCAD stores Application Related data. | C:\Documents and Settings\username\Application Data\FreeCAD\system.cfg | /home/username/.FreeCAD/system.cfg |
UserHomePath | Home path of the current user | C:\Documents and Settings\username\My Documents | /home/username |
Command line arguments
Config var name | Synopsis | Example |
---|---|---|
LoggingFile | 1 if the logging is switched on | 1 |
LoggingFileName | File name where the log is placed | C:\Documents and Settings\username\Application Data\FreeCAD\FreeCAD.log |
RunMode | This indicates how the main loop will work. "Script" means that the given script is called and then exit. "Cmd" runs the command line interpreter. "Internal" runs an internal script. "Gui" enters the Gui event loop. "Module" loads a given python module. | "Cmd" |
FileName | Meaning depends on the RunMode | |
ScriptFileName | Meaning depends on the RunMode | |
Verbose | Verbosity level of FreeCAD | "" or "strict" |
OpenFileCount | Holds the number of files opened through command line arguments | "12" |
AdditionalModulePaths | Holds the additional Module paths given in the cmd line | "extraModules/" |
Config var name | Synopsis | Example M$ | Example Posix (Linux) |
---|---|---|---|
AppHomePath | Path where FreeCAD is installed | c:/Progam Files/FreeCAD_0.7 | /user/local/FreeCAD_0.7 |
PythonSearchPath | Holds a list of paths which python search modules. This is at startup can change during execution |
Some libraries need to call system environment variables. Sometimes when there is a problem with a FreeCAD installation, it is because some environment variable is absent or set wrongly. Therefore, some important variables get duplicated in the Config and saved in the log file.
Python related environment variables:
- PYTHONPATH
- PYTHONHOME
- TCL_LIBRARY
- TCLLIBPATH
OpenCascade related environment variables:
- CSF_MDTVFontDirectory
- CSF_MDTVTexturesDirectory
- CSF_UnitsDefinition
- CSF_UnitsLexicon
- CSF_StandardDefaults
- CSF_PluginDefaults
- CSF_LANGUAGE
- CSF_SHMessage
- CSF_XCAFDefaults
- CSF_GraphicShr
- CSF_IGESDefaults
- CSF_STEPDefaults
System related environment variables:
- PATH
The table below shows the availible informations about the Build version. Most of it comes from the Subversion repository. This stuff is needed to exactly rebuild a version!
Config var name | Synopsis | Example |
---|---|---|
BuildVersionMajor | Major Version number of the Build. Defined in src/Build/Version.h.in | 0 |
BuildVersionMinor | Minor Version number of the Build. Defined in src/Build/Version.h.in | 7 |
BuildRevision | SVN Repository Revision number of the src in the Build. Generated by SVN | 356 |
BuildRevisionRange | Range of differnt changes | 123-356 |
BuildRepositoryURL | Repository URL | https://free-cad.svn.sourceforge.net/svnroot/free-cad/trunk/src |
BuildRevisionDate | Date of the above Revision | 2007/02/03 22:21:18 |
BuildScrClean | Indicates if the source was changed ager checkout | Src modified |
BuildScrMixed | Src not mixed |
These Config entries are related to the branding mechanism of FreeCAD. See Branding for more details.
Config var name | Synopsis | Example |
---|---|---|
ExeName | Name of the build Executable file. Can diver from FreeCAD if a different main.cpp is used. | FreeCAD.exe |
ExeVersion | Over all Version shows up at start time | V0.7 |
AppIcon | Icon which is used for the Executable, shows in Application MainWindow. | "FCIcon" |
ConsoleBanner | Banner which is prompted in console mode | |
SplashPicture | Name of the Icon used for the Splash Screen | "FreeCADSplasher" |
SplashAlignment | Alignment of the Text in the Splash dialog | Left" |
SplashTextColor | Color of the splasher Text | "#000000" |
StartWorkbench | Name of the Workbech which get started automaticly after Startup | "Part design" |
HiddenDockWindow | List of dockwindows (separated by a semicolon) which will be disabled | "Property editor" |